1.
J Cardiovasc Surg (Torino) ; 56(5): 745-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25990022

RESUMO

Unresolved for over half a century now since the beginning of aortic surgery spinal cord injury (SCI) remains the most devastating complication after extensive open and endovascular thoracoabdominal aortic aneurysm (TAA/A) repair. Over the past decade extensive research on spinal cord perfusion lead to a better understanding of previously unknown physiologic mechanisms involved in the suspension of the cord's arterial supply and the consecutive development of SCI underscoring the need for new concepts in treatment strategy and monitoring methods during and after TAA/A repair. Based on this knowledge, new treatment strategies in particular the staged-repair were developed. The first-in-man translation of this idea has just been published introducing the new concept: minimally invasive selective segmental artery coil-embolization. Another approach to overcome the most critical initial period after segmental artery occlusion due to stent graft deployment in the descending or thoracoabdominal aorta is temporary aneurysm sac perfusion, which also has recently been clinically trialed. Furthermore, the new non-invasive real-time monitoring method to record spinal cord viability by means of near-infrared spectroscopy of the paraspinal collateral network by means of near-infrared spectroscopy has also been suggested and successfully introduced in a pilot series to a clinical setting. This review addresses problems, unsolved questions and future perspectives regarding these three new concepts.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Traumatismos da Medula Espinal/prevenção & controle , Isquemia do Cordão Espinal/prevenção & controle , Medula Espinal/irrigação sanguínea , Animais , Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico , Aneurisma da Aorta Torácica/fisiopatologia , Humanos , Monitorização Neurofisiológica Intraoperatória/métodos , Valor Preditivo dos Testes , Fatores de Risco , Espectroscopia de Luz Próxima ao Infravermelho , Traumatismos da Medula Espinal/diagnóstico , Traumatismos da Medula Espinal/etiologia , Traumatismos da Medula Espinal/fisiopatologia , Isquemia do Cordão Espinal/diagnóstico , Isquemia do Cordão Espinal/etiologia , Isquemia do Cordão Espinal/fisiopatologia , Resultado do Tratamento
2.
Int J Cardiovasc Imaging ; 31(1): 163-9, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25165022

RESUMO

In computed tomography (CT) evaluation prior to transcatheter aortic valve implantation area- and perimeter-based calculation of the aortic annulus diameter, the so-called effective annulus diameter (ED), is the preferred parameter for decision making regarding prosthesis sizes. Currently, it is unclear how relevant the differences between the two methods of measurement are and how they are influenced by the cardiac cycle. The aim of this study was to compare area- and perimeter-based measurements in computed tomography derived aortic annulus sizing. A total of 60 patients who underwent evaluation for transcatheter aortic valve implantation were included in this study. All patients received pre-procedural ECG gated CT. The aortic annulus area and perimeter were measured and the derived ED compared using parametric statistics and Bland and Altman analysis. The mean patient age was 80.2 ± 4 years. Systolic aortic annulus area and perimeter were higher compared to diastolic results (mean difference area 12.8 ± 24 mm(2) and perimeter 0.72 ± 1 mm; p = 0.009-0.068). Both the area- and perimeter-based ED had a good agreement within two standard deviations for systolic and diastolic measurements. Effective diameter measurements derived from the area were significantly smaller compared to perimeter-based measurements (mean difference: systolic 0.72 ± 0.3 mm and diastolic 0.81 ± 0.4 mm; p < 0.001). While the area-based ED was significantly influenced by the cardiac cycle with a mean difference of 0.4 ± 0.6 mm (p = 0.009), no significant difference was found for the perimeter-based ED (mean difference: 0.2 ± 0.4; p = 0.07). For patients undergoing CT evaluation prior to transcatheter aortic valve implantation, the perimeter-based effective annulus diameter provides a reliable parameter for annulus sizing without significant affection by the cardiac cycle and therefore facilitates annulus measurements with a single heart phase. However, perimeter-based diameters of the annulus are significantly larger than area-based diameters.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/terapia , Valva Aórtica/diagnóstico por imagem , Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Tomografia Computadorizada Multidetectores/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Técnicas de Imagem de Sincronização Cardíaca , Eletrocardiografia , Feminino , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valor Preditivo dos Testes , Desenho de Prótese , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
3.
Med Eng Phys ; 36(11): 1480-6, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25183045

RESUMO

Stent graft fixation in the vessel affects the success of endovascular aneurysm repair. Thereby the radial forces of the stent, which are dependent on several factors, play a significant role. In the presented work, a finite element sensitivity study was performed. The radial forces are 29% lower when using the hyperelastic approach for the vessel compared with linear elastic assumptions. Without the linear elastic modeled plaque, the difference increases to 35%. Modeling plaque with linear elastic material approach results in 8% higher forces than with a hyperelastic characteristic. The significant differences resulting from the investigated simplifications of the material lead to the conclusion that it is important to apply an anisotropic nonlinear approach for the vessel. The oversizing study shows that radial forces increase by 64% (0.54 N) when raising the oversize from 10 to 22%, and no further increase in force can be observed beyond these values (vessel diameter D=12 mm). Starting from an oversize of 24%, the radial force steadily decreases. The findings of the investigation show that besides the oversizing the material properties, the ring design and the vessel characteristics have an influence on radial forces.


Assuntos
Ligas , Vasos Sanguíneos , Fenômenos Mecânicos , Stents , Fenômenos Biomecânicos , Análise de Elementos Finitos , Incerteza
4.
Int J Comput Assist Radiol Surg ; 9(4): 617-33, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24170574

RESUMO

PURPOSE: A new approach to optimize stent graft selection for endovascular aortic repair is the use of finite element analysis. Once the finite element model is created and solved, a software module is needed to view the simulation results in the clinical work environment. A new tool for interpretation of simulation results, named Medical Postprocessor, that enables comparison of different stent graft configurations and products was designed, implemented and tested. METHODS: Aortic endovascular stent graft ring forces and sealing states in the vessel landing zone of three different configurations were provided in a surgical planning software using the Medical Imaging Interaction Tool Kit (MITK) software system. For data interpretation, software modules for 2D and 3D presentations were implemented. Ten surgeons evaluated the software features of the Medical Postprocessor. These surgeons performed usability tests and answered questionnaires based on their experience with the system. RESULTS: The Medical Postprocessor visualization system enabled vascular surgeons to determine the configuration with the highest overall fixation force in 16+/-6 s, best proximal sealing in 56+/-24s and highest proximal fixation force in 38+/- s. The majority considered the multiformat data provided helpful and found the Medical Postprocessor to be an efficient decision support system for stent graft selection. The evaluation of the user interface results in an ISONORM-conform user interface (113.5 points). CONCLUSION: The Medical Postprocessor visualization software tool for analyzing stent graft properties was evaluated by vascular surgeons. The results show that the software can assist the interpretation of simulation results to optimize stent graft configuration and sizing.


Assuntos
Aorta/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Procedimentos Endovasculares/métodos , Análise de Elementos Finitos , Processamento de Imagem Assistida por Computador/métodos , Software , Stents , Humanos , Resultado do Tratamento
5.
Eur J Vasc Endovasc Surg ; 46(6): 651-6, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24099957

RESUMO

OBJECTIVE: The aim of this study was to evaluate the feasibility of non-invasive monitoring of the paraspinous collateral network (CN) oxygenation prior to, during, and after thoracoabdominal aortic repair in a clinical series. METHODS: Near-infrared spectroscopy optodes were positioned bilaterally-over the thoracic and lumbar paraspinous vasculature-to transcutaneously monitor muscle oxygenation of the CN in 20 patients (age: 66 ± 10 years; men = 11) between September 2010 and April 2012; 15 had open thoracoabdominal aortic repair (Crawford II and III), three had thoracic endovascular aortic repair (TEVAR; Crawford I), and two had a hybrid repair (Crawford II). CN oxygenation was continuously recorded until 48 hours postoperatively. RESULTS: Hospital mortality was 5% (n = 1), 15% suffered ischemic spinal cord injury (SCI). Mean thoracic CN oxygenation saturation was 75.5 ± 8% prior to anesthesia (=baseline) without significant variations throughout the procedure (during non-pulsatile cooling on cardiopulmonary bypass and with aortic cross-clamping; range = 70.6-79.5%). Lumbar CN oxygenation (LbS) dropped significantly after proximal aortic cross-clamping to a minimum after 11.7 ± 4 minutes (74 ± 13% of baseline), but fully recovered after restoration of pulsatile flow to 98.5% of baseline. During TEVAR, stent-graft deployment did not significantly affect LbS. Three patients developed relevant SCI (paraplegia n = 1/paraparesis n = 2). In these patients LbS reduction after aortic cross-clamping was significantly lower compared with patients who did not experience SCI (p = .041). CONCLUSIONS: Non-invasive monitoring of CN oxygenation prior to, during, and after thoracoabdominal aortic repair is feasible. Lumbar CN oxygenation levels directly respond to compromise of aortic blood circulation.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Circulação Colateral , Isquemia/prevenção & controle , Monitorização Intraoperatória/métodos , Espectroscopia de Luz Próxima ao Infravermelho , Medula Espinal/irrigação sanguínea , Idoso , Aorta Abdominal/cirurgia , Aorta Torácica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Estudos de Viabilidade , Feminino , Mortalidade Hospitalar , Humanos , Isquemia/etiologia , Masculino , Músculo Esquelético/irrigação sanguínea , Paraplegia/etiologia , Paraplegia/prevenção & controle , Paresia/etiologia , Paresia/prevenção & controle , Projetos Piloto , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Stents
SELEÇÃO DE REFERÊNCIAS